International Radiation Detectors, Inc.
AXUV Photodiode arrays
|
Sensitive Area (mm2) |
Size (mm) |
Package Type |
Shunt Resistance (M-Ohm) |
Dark Current @ 50V |
Capacitance @ 0V |
Risetime (10-90%) |
| AXUV-3ELA# |
1 (x3) |
1 x 1 (x3) |
Ceramic |
1000 |
300 pA |
25 pF |
2 nSec |
| AXUV-10EL# |
1 (x10) |
1 x 1 (x10) |
Ceramic |
1000 |
10 nA |
25 pF |
1 nSec |
| AXUV-16ELO/G |
10 (x16) |
2 x 5 (x16) |
Ceramic |
100 |
* |
2 nF** |
0.5 µSec** |
| AXUV-16EL |
10 (x16) |
2 x 5 (x16) |
Ceramic |
100 |
* |
2 nF** |
0.5 µSec** |
| AXUV-20EL |
3 (x20) |
.75 x 4 (x20) |
Ceramic |
300 |
* |
1 nF** |
0.2 µSec** |
| AXUV-20ELM |
3 (x20) |
.75 x 4 (x20) |
Ceramic |
300 |
* |
1 nF** |
0.2 µSec** |
| AXUV-22EL |
4 (x22) |
1 x 4 (x22) |
Ceramic |
200 |
* |
1 nF** |
0.2 µSec** |
| Notes: |
# Use with 10-50 volts bias. |
|
* May be selected for a specific application. |
|
** Devices with better values may be selected. |
References:
1] R.L. Boivin, J.A. Goetz, E.S. Marmar, J.E. Rice and J.L. Terry, "High Resolution Bolometry on the
Alcator C-Mod Tokamak (Invited)"
Rev. Sci. Instrum. Vol 70 (1), 260-264 (1999)
2] I. Furno et.al. , “Fast bolometric measurements on the TCV Tokamak”
Rev. of Sci. Instrum. Vol. 70 (12), 4552-4556 (1996)
3] D.S. Gray et.al., “Time resolved radiated power during tokamak disruptions and spectral averaging of AXUV photodiode response in
DIII-D”
Rev. of Sci. Instrum., Vol. 75, no. 2, 376-381 (2004)
|